Basic master
Fine sandblasting unit
Advantages
- Homogeneous and tension-free surfaces thanks to the special mixing chamber technology (Venturi principle), regardless of the fill level of the sandblasting tank.
- High economic efficiency as there is no unnecessary after-flow of sandblasting material.
- Targeted, precise sandblasting due to excellent illumination of the blasting chamber with LED technology.
Details
- Large sandblasting chamber (20 l) allows ample freedom of movement.
- Good, long-lasting visibility of the objects through silicone-coated glass panel (10x longer service life).
Basic master, 25-70 µm/25-70 µm, 220-240 V
2 x 25–70 μm, incl. 2 nozzles 0.8 mm
Basic master, 25-70 µm/70-250 µm, 220-240 V
1 x 25–70 µm, 1 x 70–250 µm, incl. 2 nozzles 0.8 mm / 1.2 mm
Basic master, 70-250 µm/70-250 µm, 220-240 V
2 x 70–250 μm, incl. 2 nozzles 1.2 mm
Basic master, 25-70 µm/25-70 µm, 100-120 V
2 x 25–70 μm, incl. 2 nozzles 0.8 mm
Basic master, 25-70 µm/25-70 µm, 220-240 V | Basic master, 25-70 µm/70-250 µm, 220-240 V | Basic master, 70-250 µm/70-250 µm, 220-240 V | Basic master, 25-70 µm/25-70 µm, 100-120 V | Basic master, 25-70 µm/70-250 µm, 100-120 V | |
---|---|---|---|---|---|
Item number | 29482000 | 29482025 | 29482250 | 29484000 | 29484025 |
Use | Fine sandblasting | Fine sandblasting | Fine sandblasting | Fine sandblasting | Fine sandblasting |
Permissible mains voltage | 220 - 240 V | 220 - 240 V | 220 - 240 V | 100 - 120 V | 100 - 120 V |
Permissible mains frequency | 50 - 60 Hz | 50 - 60 Hz | 50 - 60 Hz | 50 - 60 Hz | 50 - 60 Hz |
Working pressure | 1 - 6 bar 14.5 - 87 psi |
1 - 6 bar 14.5 - 87 psi |
1 - 6 bar 14.5 - 87 psi |
1 - 6 bar 14.5 - 87 psi |
1 - 6 bar 14.5 - 87 psi |
Connection pressure | 6 - 8 bar 87 - 116 psi |
6 - 8 bar 87 - 116 psi |
6 - 8 bar 87 - 116 psi |
6 - 8 bar 87 - 116 psi |
6 - 8 bar 87 - 116 psi |
Nominal voltage | 230 V | 230 V | 230 V | 120 V | 120 V |
Volume flow (max.) | 98 l/min 3.46 cfm |
98 l/min 3.46 cfm |
98 l/min 3.46 cfm |
98 l/min 3.46 cfm |
98 l/min 3.46 cfm |
Lamp power | 16 W | 16 W | 16 W | 16 W | 16 W |
Intensity of lighting (max., at 43 cm distance) | 4,800 lx | 4,800 lx | 4,800 lx | 4,800 lx | 4,800 lx |
Number of tanks | 2 | 2 | 2 | 2 | 2 |
Blasting chamber volume | 20 l 5.3 gal |
20 l 5.3 gal |
20 l 5.3 gal |
20 l 5.3 gal |
20 l 5.3 gal |
Silicone-coated panel | yes | yes | yes | yes | yes |
- Item number
- 29482000
- Use
- Fine sandblasting
- Permissible mains voltage
- 220 - 240 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 230 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
- Item number
- 29482025
- Use
- Fine sandblasting
- Permissible mains voltage
- 220 - 240 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 230 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
- Item number
- 29482250
- Use
- Fine sandblasting
- Permissible mains voltage
- 220 - 240 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 230 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
- Item number
- 29484000
- Use
- Fine sandblasting
- Permissible mains voltage
- 100 - 120 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 120 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
- Item number
- 29484025
- Use
- Fine sandblasting
- Permissible mains voltage
- 100 - 120 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 120 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
Technical data
Basic master, 25-70 µm/25-70 µm, 220-240 V | Basic master, 25-70 µm/70-250 µm, 220-240 V | Basic master, 70-250 µm/70-250 µm, 220-240 V | Basic master, 25-70 µm/25-70 µm, 100-120 V | Basic master, 25-70 µm/70-250 µm, 100-120 V | |
---|---|---|---|---|---|
Item number | 29482000 | 29482025 | 29482250 | 29484000 | 29484025 |
Use | Fine sandblasting | Fine sandblasting | Fine sandblasting | Fine sandblasting | Fine sandblasting |
Permissible mains voltage | 220 - 240 V | 220 - 240 V | 220 - 240 V | 100 - 120 V | 100 - 120 V |
Permissible mains frequency | 50 - 60 Hz | 50 - 60 Hz | 50 - 60 Hz | 50 - 60 Hz | 50 - 60 Hz |
Working pressure | 1 - 6 bar 14.5 - 87 psi |
1 - 6 bar 14.5 - 87 psi |
1 - 6 bar 14.5 - 87 psi |
1 - 6 bar 14.5 - 87 psi |
1 - 6 bar 14.5 - 87 psi |
Connection pressure | 6 - 8 bar 87 - 116 psi |
6 - 8 bar 87 - 116 psi |
6 - 8 bar 87 - 116 psi |
6 - 8 bar 87 - 116 psi |
6 - 8 bar 87 - 116 psi |
Nominal voltage | 230 V | 230 V | 230 V | 120 V | 120 V |
Volume flow (max.) | 98 l/min 3.46 cfm |
98 l/min 3.46 cfm |
98 l/min 3.46 cfm |
98 l/min 3.46 cfm |
98 l/min 3.46 cfm |
Lamp power | 16 W | 16 W | 16 W | 16 W | 16 W |
Intensity of lighting (max., at 43 cm distance) | 4,800 lx | 4,800 lx | 4,800 lx | 4,800 lx | 4,800 lx |
Number of tanks | 2 | 2 | 2 | 2 | 2 |
Blasting chamber volume | 20 l 5.3 gal |
20 l 5.3 gal |
20 l 5.3 gal |
20 l 5.3 gal |
20 l 5.3 gal |
Silicone-coated panel | yes | yes | yes | yes | yes |
- Item number
- 29482000
- Use
- Fine sandblasting
- Permissible mains voltage
- 220 - 240 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 230 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
- Item number
- 29482025
- Use
- Fine sandblasting
- Permissible mains voltage
- 220 - 240 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 230 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
- Item number
- 29482250
- Use
- Fine sandblasting
- Permissible mains voltage
- 220 - 240 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 230 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
- Item number
- 29484000
- Use
- Fine sandblasting
- Permissible mains voltage
- 100 - 120 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 120 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
- Item number
- 29484025
- Use
- Fine sandblasting
- Permissible mains voltage
- 100 - 120 V
- Permissible mains frequency
- 50 - 60 Hz
- Working pressure
-
1 - 6 bar
14.5 - 87 psi - Connection pressure
-
6 - 8 bar
87 - 116 psi - Nominal voltage
- 120 V
- Volume flow (max.)
-
98 l/min
3.46 cfm - Lamp power
- 16 W
- Intensity of lighting (max., at 43 cm distance)
- 4,800 lx
- Number of tanks
- 2
- Blasting chamber volume
-
20 l
5.3 gal - Silicone-coated panel
- yes
Cobra, 110 µm
100 µm (170–100 mesh)
12.5 kg bucket (27.6 lbs.)
Cobra, 125 µm
90–125 µm (200–115 mesh)
12.5 kg bucket (27.6 lbs.)
Cobra, 250 µm
250 µm (60 mesh)
12.5 kg bucket (27.6 lbs.)
Cobra, 50 µm
50 µm (270 mesh)
12.5 kg bucket (27.6 lbs.)
Cobra, 110 µm
90–125 µm (200–115 mesh)
5 kg canister (11.04 lbs.)
Cobra, 90 µm
90–125 µm (200–115 mesh)
5 kg canister (11.04 lbs.)
Cobra, 250 µm
250 µm (60 mesh)
5 kg canister (11.04 lbs.)
Cobra, 125 µm
90–125 µm (200–115 mesh)
5 kg canister (11.04 lbs.)
Cobra, 25 µm
25 µm (450 mesh)
5 kg canister (11.04 lbs.)
Cobra, 50 µm
50 µm (270 mesh)
5 kg canister (11.04 lbs.)
Rolloblast, 100µm
100 µm (170–100 mesh)
5 kg canister (11.04 lbs.)
Rolloblast, 50 µm
50 µm (400–200 mesh)
5 kg canister (11.04 lbs.)
Retrofit tank, 25–70 μm
Tank assembly in only a few steps. Tool-free tank extension via quick-release coupling and color-coded system. Individual design of the tank for 25–70 µm or 70–250 µm abrasives. Transparent tank for checking the filling Level.
1 x 25–70 µm, incl. nozzle 0.8 mm
Retrofit tank, 70–250 µm
Tank assembly in only a few steps. Tool-free tank extension via quick-release coupling and color-coded system. Individual design of the tank for 25–70 µm or 70–250 µm abrasives. Transparent tank for checking the filling Level.
1 x 70–250 μm, incl. nozzle 1.2 mm
IT sandblasting nozzle Ø 0.40 mm
Blasting nozzles for the Basic units
▪️ highly recommended for Cobra 25 (μm)
1 piece
IT sandblasting nozzle Ø 0.60 mm
Blasting nozzles for the Basic units
▪️ highly recommended for Cobra 50, Rolloblast 50, 3M EspeSoft (μm)
1 piece
IT sandblasting nozzle Ø 0.80 mm
Blasting nozzles for the Basic units
▪️ highly recommended for Cobra 90 (μm)
▪️ recommended for Cobra 50, 110, Rolloblast 50,100, 3M EspeSoft (μm)
1 piece
IT sandblasting nozzle Ø 1.00 mm
Blasting nozzles for the Basic units
▪️ highly recommended for Cobra 110, Rolloblast 100 (μm)
▪️ recommended for Cobra 90, 125, Rocatec Pre&Plus (μm)
1 piece
IT sandblasting nozzle Ø 1.20 mm
Blasting nozzles for the Basic units
▪️ highly recommended for Cobra 125, Rocatec Pre&Plus (μm)
▪️ recommended for Cobra 50, 90, 110, 250, Rolloblast 100 (μm)
1 piece
IT sandblasting nozzle Ø 1.40 mm
Blasting nozzles for the Basic units
▪️ highly recommended for Cobra 125 (μm)
▪️ recommended for Cobra 110, 250, Rocatec Pre&Plus (μm)
1 piece
IT sandblasting nozzle Ø 2.00 mm
Blasting nozzles for the Basic units
▪️ highly recommended for Cobra 250 (μm)
1 piece
IT Slotted nozzle Ø 1.5x 3.5 mm
Blasting nozzles for the Basic units
▪️ highly recommended for Cobra 110, 125, 250, Rolloblast 100 (μm)
1 piece
-
Catalogue
RENFERT_CATALOG_EN.PDFPDF (29.53MB) -
Safety data sheet
Safety data sheet
Safety data sheet
Safety data sheet
Safety data sheet
Wärmeleitpaste 31955 DEWärmeleitpaste 31955 ENWärmeleitpaste 31955 ESWärmeleitpaste 31955 FRWärmeleitpaste 31955 ITPDF (617KB)PDF (613KB)PDF (614KB)PDF (616KB)PDF (612KB) -
Manual / User guide
Manual / User guide
Sandblasting nozzles & abrasive agents / Strahlmitel - Strahldüsen KombinationSandblasting nozzles & abrasive agents / Strahlmitel - Strahldüsen KombinationPDF (18KB)PDF (18KB) -
Brochures
Brochures
Brochures
Brochures
Brochures
Brochures
Brochures
Basic sandblaster | Brochure | DEBasic sandblaster | BrochureBasic sandblaster | BrochureBasic sandblaster | BrochureBasic sandblaster | BrochureBasic sandblaster | BrochureBasic sandblaster | BrochurePDF (2.22MB)PDF (2.22MB)PDF (2.22MB)PDF (2.22MB)PDF (2.22MB)PDF (2.22MB)PDF (2.22MB) -
Repair manual
Repair manual
Basic master 2946xxxx | CBasic master 2946xxxx | CPDF (565KB)PDF (522KB) -
Declaration of conformity
UKCA Basic sandblasting units / DustexPDF (393KB) -
Repair manual
Basic master 2948xxxx | A/BPDF (16.33MB)Multilingual -
FAQ
Basic master 294xxxxxPDF (1.05MB)Multilingual -
Instruction manual
Basic master 294xxxxxPDF (10.64MB)Multilingual -
Instruction manual
Cleaning the dosing nozzlePDF (1.54MB)Multilingual -
Instruction manual
Basic master 294xxxxxPDF (11.69MB)Multilingual -
Declaration of conformity
Basic master 294xxxxxPDF (831KB)Multilingual